UL 83A-2016 pdf download – STANDARD FOR SAFETY Flouropolymer Insulated Wire

02-08-2022 comment

UL 83A-2016 pdf download – STANDARD FOR SAFETY Flouropolymer Insulated Wire.
1 Scope 1 .1 This Standard specifies the requirements for 600 V, single-conductor, flouropolymer-insulated wires and cables in accordance with NFPA 70, National Electrical Code (NEC). Note: See Appendix A for the complete list of wire types covered by this Standard. 1 .2 Products for which this Standard provides requirements might have applications not described in the electrical code listed in 1 .1 . 2 General 2.1 Units of measure 2.1 .1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.2 Reference publications 2.2.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. UL Standards UL 1 685 Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables UL 2556 Wire and Cable Test Methods ASTM (American Society for Testing and Materials) Standards B3-1 3, Standard Specification for Soft or Annealed Copper Wire B8-1 1 , Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft B33-1 0(201 4), Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes B1 60-1 0(201 4), Standard Specification for Nickel Rod and Bar B1 72-1 0(201 5), Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors B1 73-1 0(201 5), Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors
4 Construction 4.1 Conductors 4.1 .1 General 4.1 .1 .1 Circuit and equipment-grounding conductors shall be of copper or of a nickel-based alloy. 4.1 .2 Copper conductors 4.1 .2.1 General 4.1 .2.1 .1 The requirements of 4.1 .2.2 or 4.1 .2.3 shall apply to solid conductors or the individual wires of stranded conductors prior to stranding. 4.1 .2.2 Bare copper conductors 4.1 .2.2.1 Each wire in a bare copper conductor shall comply with the requirements of ASTM B3. 4.1 .2.3 Tin-coated copper conductors 4.1 .2.3.1 Each wire in a tin-coated conductor shall comply with the requirements of ASTM B33. Overcoating of 2.08 mm 2 (1 4 AWG), 3.31 mm 2 (1 2 AWG), and 5.26 mm 2 (1 0 AWG) stranded copper conductor with a layer of tin shall be optional. 4.1 .2.4 Nickel-base alloy conductors 4.1 .2.4.1 Each wire in a nickel-base alloy conductor shall comply with the requirements of ASTM B1 60. 4.1 .2.5 Nickel-coated copper conductors 4.1 .2.5.1 Each solid copper conductor and each strand in a stranded copper conductor shall be protected against oxidation by a coating of nickel complying with ASTM B355

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems) UL Standards free download

BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems)

BS IEC 63085:2021 pdf download - Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems). 3.6 identification result data including the common name of the inspected and identified liquid...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information