IEEE Std C37.122.1-2014 pdf download – IEEE Guide for Gas-Insulated Substations Rated Above 52 kV.
1. Scope This guide provides information of special relevance to planning, design, testing, installation, operation and maintenance of gas-insulated substations (GISs) and equipment. This guide is intended to supplement IEEE Std C37.122™ 1 . This guide is applicable to all GISs above 52 kV. However, the importance of topics covered varies with application category. For example, the issues related to advanced field test techniques and very fast transients (VFT) are of particular interest for extra-high voltage (EHV) GISs. 2. Normative references The following referenced documents are indispensable for the application of this document (i.e., they must be understood and used, so each referenced document is cited in text and its relationship to this document is explained). For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments or corrigenda) applies. ASTM D2472-00 Standard Specification for Sulfur Hexafluoride. 2 CIGRE 69-1992, General Guidelines for the Design of Outdoor AC Substations.
IEC 62271-100, High-Voltage Switchgear and Controlgear—Part 100: High-Voltage Alternating Current Circuit Breakers. IEC 62271-102, High-Voltage Switchgear and Controlgear—Part 102: High Voltage Alternating Current Disconnectors and Earthing Switches. IEC 62271-203, High-Voltage Switchgear and Controlgear—Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. IEC 62271-205, High-Voltage Switchgear and Controlgear—Part 205: Compact Switchgear Assemblies for Operation at Rated Voltages Above 52 kV. IEC 62271-209, High-Voltage Switchgear and Controlgear—Part 209: Cable connections for Gas-Insulated Metal-Enclosed Switchgear for Rated Voltages Above 52 kV—Fluid-Filled and Extruded Insulation Cables—Fluid-Filled and Dry-Type Cable-Terminations. IEC 62271-211, High-Voltage Switchgear and Controlgear—Part 211: Direct Connection Between Power Transformers and Gas-Insulated Metal Enclosed Switchgear for Rated Voltages Above 52 kV. IEEE Std 80™, IEEE Guide for Safety in AC Substation Grounding. 5, 6 IEEE Std 605™, IEEE Guide for Bus Design in Air Insulated Substations. IEEE Std 693™, IEEE Recommended Practice for Seismic Design of Substations. IEEE Std 1300™, IEEE Guide for Cable Connections for Gas-Insulated Substations. IEEE Std C37.04™, IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers. IEEE Std C37.06™, IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis—Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V. IEEE Std C37.09™, IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis. IEEE Std C37.010™, IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis.
IEEE Std C37.122.1-2014 pdf download – IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
Note:
If you can share this website on your Facebook,Twitter or others,I will share more.