UL 486E-2009 pdf download – Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors

02-12-2022 comment

UL 486E-2009 pdf download – Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors.
7.1 .5 Conductor sizes 30 – 20 AWG (0.05 – 0.52 mm 2 ) need not be subjected to the secureness test in the static-heating sequence or mechanical sequence. 7.1 .6 Specimen sets shall be subjected to the test sequences using the conductor material specified in Table 3 for the one or more conductor material combinations for which the equipment wiring terminal is intended. The stress corrosion tests shall be permitted to be conducted using either copper or aluminum conductor. When an equipment wiring terminal is rated for copper-to-copper, aluminum-to-aluminum, and copper-to-aluminum (intermixed), the mechanical sequence with copper-to-aluminum conductors may be omitted. 7.1 .7 For an equipment wiring terminal intended to be used with aluminum, copper-clad aluminum, and copper wire (marked ″AL-CU″ on the equipment wiring terminal or the end use equipment), sample sets with aluminum wire and copper wire are to be subjected to the test sequence in Table 1 or Table 2. For an equipment wiring terminal intended to be used with copper-clad aluminum wire and copper wire (marked ″CC-CU″ on the equipment wiring terminal or the end use equipment), sample sets with copper-clad aluminum wire and copper wire are to be subjected to the test sequence in Table 1 or Table 2. For a terminal intended to be used with copper wire only, sample sets with copper wire are to be subjected to the test sequence in Table 1 or Table 2. 7.1 .8 Tests with aluminum wire are representative of tests with copper-clad aluminum wire. 7.1 .9 An equipment wiring terminal rated for Class 5 and 6 metric conductors (flexible stranded) shall be subjected to all test sequences using flexible metric conductors. 7.1 .1 0 For an equipment wiring terminal intended to be used with aluminum and copper conductor, specimens with aluminum conductor and copper conductor shall be subjected to the current-cycling, static-heating sequence, and mechanical sequence tests.7.1 .1 1 For an aluminum-bodied equipment wiring terminal intended to be used with copper conductor only, specimens with copper conductor shall be subjected to the current-cycling, static-heating sequence, and mechanical sequence tests. 7.1 .1 2 Tests conducted on an equipment wiring terminal with compact-stranded conductors shall represent tests with concentric and compressed stranded conductors of the same size.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems) UL Standards free download

BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems)

BS IEC 63085:2021 pdf download - Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems). 3.6 identification result data including the common name of the inspected and identified liquid...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information