UL 83-2008 pdf download – Thermoplastic-Insulated Wires and Cables

02-12-2022 comment

UL 83-2008 pdf download – Thermoplastic-Insulated Wires and Cables.
4.1 .5 Sizes and stranding 4.1 .5.1 Sizes Conductors shall be as shown in Table 1 . Note: IEC conductor sizes are not recognized in the CEC, NEC, or NOM-001 -SEDE; however, these sizes may be required for wires and cables intended for use outside of the codes. As a guide to users of this Standard, information on IEC conductors is provided in Annex F. 4.1 .5.2 Stranding 4.1 .5.2.1 General The minimum number of wires (strands) in a conductor shall be in accordance with Table 2. Copper strands smaller than 0.01 27 mm 2 (36 AWG) and aluminum strands smaller than 0.324 mm 2 (22 AWG) shall not be used. A compact- stranded conductor shall not be segmented. 4.1 .5.2.2 Compact A compact-stranded conductor shall be a round conductor consisting of a central core surrounded by one or more layers of helically laid wires, and formed into a smooth outermost layer by rolling, drawing, or other means. The lay length of every layer shall be not less than 8 times nor more than 1 6 times the outside diameter of the completed conductor, except that for sizes 33.6 mm 2 (2 AWG) and smaller, the maximum lay length shall be 1 7.5 times the outside diameter. The direction of lay of the outermost layer shall be left-hand, and it shall be reversed or unidirectional/unilay in successive layers. 4.1 .5.2.3 Compressed A compressed-stranded conductor shall be a round conductor consisting of a central core surrounded by one or more layers of helically laid wires with either the direction of lay reversed in successive layers or unilay or unidirectional lay. The direction of lay of the outer layer shall be left-hand in all cases. The strands of one or more layers shall be slightly compressed by rolling, drawing, or other means to change the originally round strands to various shapes that achieve filling of some of the spaces originally present between the strands.
4.1 .5.2.5 Length and direction of lay Every stranded conductor other than a compact-stranded conductor or a bunch-stranded conductor twisted as a single bunch shall comply with the following: a) The direction of lay of the strands, members, or ropes in a 1 3.3 – 1 01 0 mm 2 (6 AWG – 2000 kcmil) conductor, other than a combination unilay or a compressed unilay or compressed unidirectional lay conductor, shall be reversed in successive layers. Rope-lay conductors with bunch-stranded or concentric-stranded members shall be either unidirectional or reversed. All unidirectional lays and the outer layer of reversed lays shall be in the left-hand direction.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems) UL Standards free download

BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems)

BS IEC 63085:2021 pdf download - Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems). 3.6 identification result data including the common name of the inspected and identified liquid...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information